Cookie preferences
This website uses cookies, which are necessary for the technical operation of the website and are always set. Other cookies, which increase the comfort when using this website, are used for direct advertising or to facilitate interaction with other websites and social networks, are only set with your consent.
Suitable for stationary installation in buildings, train stations, structures, and systems, even... more
Suitable for stationary installation in buildings, train stations, structures, and systems, even under conditions of increased electromagnetic interference.
Features
- Conductor: copper AWG23 Ø 0.55 mm
- Insulation: Skin-Foam-Skin PE
- Pair of shielding: aluminum/polyester film
- Braid shielding: tinned copper braid
- Outer sheath: LSZH, cable dimensions 6.5 mm x 13.3 mm
Parameter
- Capacity: pF/m = 56
- Drag imbalance:% 2
- Insulation resistance: GOhm/km = 5
- DC resistance: Hm/km = 84
- Signal propagation speed: s 0.80
- Propagation delay: ns/100 m = 534 + 36/vf
- Delay shift on the frequency 100 MHz: ns/100 m = 30
- Test voltage between the wires, (DC, 2 s): kV 2.5
- Characteristic impedance: Ohm 100 ± 15
- Shielding class: S/FTP
- Specification: CAT 7
- Cable Length: 250 m
- Color: Orange
- AWG: 23/1
- After installation: -40° C to +60° C
- During installation: -10° C to +60° C
Delivery
1x Network Cable Dublex CAT 7 S/FTP PiMF, 250m
Features
- Conductor: copper AWG23 Ø 0.55 mm
- Insulation: Skin-Foam-Skin PE
- Pair of shielding: aluminum/polyester film
- Braid shielding: tinned copper braid
- Outer sheath: LSZH, cable dimensions 6.5 mm x 13.3 mm
Parameter
- Capacity: pF/m = 56
- Drag imbalance:% 2
- Insulation resistance: GOhm/km = 5
- DC resistance: Hm/km = 84
- Signal propagation speed: s 0.80
- Propagation delay: ns/100 m = 534 + 36/vf
- Delay shift on the frequency 100 MHz: ns/100 m = 30
- Test voltage between the wires, (DC, 2 s): kV 2.5
- Characteristic impedance: Ohm 100 ± 15
- Shielding class: S/FTP
- Specification: CAT 7
- Cable Length: 250 m
- Color: Orange
- AWG: 23/1
- After installation: -40° C to +60° C
- During installation: -10° C to +60° C
Delivery
1x Network Cable Dublex CAT 7 S/FTP PiMF, 250m
Related links to "Network Cable Duplex CAT 7 (Installation Cable, S/FTP, LSZH, LAN 1000MHz, Orange, 250m)"
Read, write and discuss reviews... more
Customer evaluation for "Network Cable Duplex CAT 7 (Installation Cable, S/FTP, LSZH, LAN 1000MHz, Orange, 250m)"
Write an evaluation
Evaluations will be activated after verification.